MCB

MCB Manufacturer — AC & DC Miniature Circuit Breakers

TPKELE manufactures AC and DC miniature circuit breakers for low voltage distribution boards, photovoltaic strings and battery energy storage. Our DZ47 / DZ47Z series cover 1P–4P pole configurations, 6A–63A current ratings and B / C / D trip curves, with breaking capacities up to 10kA. AC models are designed to IEC 60898-1; DC models follow IEC 60947-2. Trusted by solar EPCs, electrical distributors and panel builders across Europe, the Middle East, Southeast Asia and South America.

  • AC MCB & DC MCB series for distribution and solar / BESS applications
  • 1P / 2P / 3P / 4P pole configurations, 6A–63A rated currents
  • B / C / D trip curves, 6kA / 10kA breaking capacity
Residential & commercial distribution boardsSolar PV string protection (DC MCB)Battery energy storage systems (BESS)Industrial panel buildingInfrastructure & data center distribution
MCB products

MCB Product Lines

Frequently Asked Questions

What is the difference between AC MCB and DC MCB?

AC MCBs are designed for alternating current circuits — the AC zero-crossing helps extinguish arcs naturally. DC MCBs handle direct current with no zero-crossing, requiring specialized arc-quenching contact structures and magnets. Solar PV strings, batteries and DC bus systems must use DC MCBs rated for the system Uoc.

What system voltages do your DC MCBs cover?

Standard DC MCBs cover up to 1000V DC; for utility-scale PV we offer up to 1500V DC versions using 3P / 4P series configuration.

Which curve should I choose — B, C or D?

B curve (3–5 In) for resistive loads, C curve (5–10 In) for general-purpose distribution and mixed loads, D curve (10–20 In) for inductive loads with high inrush currents like motors and transformers.

Do you support OEM branding for MCBs?

Yes — logo printing, custom housing color, dedicated packaging and private-label catalogs are supported for distributor and brand-owner programs.

Do your MCBs carry CE certification?

Yes, TPKELE MCBs are CE & RoHS compliant. AC models are tested per IEC 60898-1; DC models per IEC 60947-2. Test reports are available for project tenders and customs documentation.

How do I coordinate MCB with SPD and voltage protector in a distribution board?

Standard protection layout from upstream to downstream: (1) Main incomer AC MCB (80A–125A), (2) AC SPD Type 2 at incoming supply for surge protection, (3) Branch AC MCBs (6A–63A) for each circuit, (4) Voltage protectors on sensitive circuits downstream of branch MCBs. This sequence provides short-circuit protection (MCB), transient surge protection (SPD) and sustained voltage quality protection (voltage protector). For circuit-level earth leakage protection, use RCBOs instead of MCBs. View our AC SPD and voltage protector series.

What is the difference between AC MCB breaking capacity 6kA and 10kA?

Breaking capacity (Icn or Icu) is the maximum short-circuit current the MCB can safely interrupt. 6kA breaking capacity is standard for residential and light commercial distribution where fault current is limited by upstream impedance. 10kA is specified for commercial, industrial and high-rise buildings where higher fault currents are possible. Check the prospective short-circuit current (Isc) at the point of installation — the MCB breaking capacity must exceed Isc. When in doubt, 10kA models provide greater safety margin with minimal cost difference.

Can I use AC MCB for DC circuits or DC MCB for AC circuits?

No — AC and DC circuit breakers are not interchangeable. AC MCBs rely on the AC current zero-crossing to extinguish arcs; DC has no zero-crossing and requires specialized arc-quenching chambers and magnetic blowout. Using an AC MCB on a DC circuit (such as solar PV or battery) can result in failure to interrupt fault current, arc flash and fire hazard. Always use DC-rated MCBs for DC applications. AC MCBs are suitable only for AC distribution. View our DC MCB series for solar and battery applications.