MCB / DC MCB

DC MCB 2P

TPKELE DC MCB 2P is a two-pole DC miniature circuit breaker for PV string positive and negative line protection in DC distribution and combiner boxes.

Key Features

  • 2 Pole DC
  • PV +/− protection
  • DC arc breaking design
  • DIN rail mount
  • CE & RoHS certified – accepted in EU, UK, and global markets

Need full datasheet, drawing or certificates for tender?

Typical Applications

Residential & commercial distribution boardsSolar PV string protection (DC MCB)Battery energy storage systems (BESS)Industrial panel buildingInfrastructure & data center distribution

DC MCB Technical Parameters

No.Parameter CategoryKey Specifications
01Core Electrical RatingsRated Current: 1A–125A | Rated Voltage: DC 250V / 500V / 800V / 1000V / 1200V / 1500VPoles: 1P / 2P / 3P / 4P | Breaking Capacity: 4.5kA / 6kA / 10kA / 15kA / 20kARated Insulation Voltage (Ui): 500V / 1000V / 1500V | Rated Impulse Withstand Voltage (Uimp): 4kV / 6kV / 8kVFrequency: DC
02Trip & Protection CharacteristicsProtection Types: Overload Protection and Short Circuit ProtectionTrip Curves: B Curve (3–5×In), C Curve (5–10×In), D Curve (10–20×In)Typical Use: C Curve for general DC distribution, PV and battery storage
03Voltage & Pole Configuration1P: DC 250V / 500V | 2P: DC 500V / 1000V3P: DC 750V / 1000V / 1200V | 4P: DC 1000V / 1500VMulti-pole designs improve safe DC arc interruption
04Mechanical & Installation DataMounting: 35mm DIN Rail | Cable Capacity: 1–25mm² / 1–35mm² / 1–50mm²Terminal Torque: typically 2.0–3.5 N·m | Mechanical Life: 10,000–20,000 cyclesElectrical Life: 1,500–6,000 cycles | Protection Degree: IP20Ambient Temperature: -25°C to +70°C
05Materials & Safety FeaturesHousing Material: Flame-retardant PA66, typically UL94 V-0 | Contact Material: Silver AlloyArc Extinguishing: Special DC arc-quenching system | Polarity: polarity-sensitive on some modelsStatus Indication: red/green window | Isolation Function: available on selected models
06Standards & ApplicationsStandards: IEC 60947-2, IEC 60898-2, EN 60947-2, UL 489BApplications: Solar PV strings, combiner boxes, battery energy storage systems, DC distribution, EV charging, control cabinets

Mechanical & Installation Parameters

ParameterCommon Requirement
Mounting35mm DIN rail
TerminalTop & bottom wiring, copper wire / busbar connection
Cable Capacity1–25mm² / 1–35mm² / 1–50mm²
Torque2.0–3.5 N·m, depends on model
Mechanical Life10,000–20,000 cycles
Electrical Life1,500–6,000 cycles
Protection DegreeIP20 (typical)
Ambient Temperature-25°C to +70°C (typical)

Materials & Safety Parameters

ParameterCommon Requirement
Housing MaterialFlame-retardant nylon / PA66, typically UL94 V-0
Contact MaterialSilver alloy contacts preferred
Arc Extinguishing SystemDC circuit breakers must have a dedicated arc-quenching structure
PolaritySome DC MCBs are polarized (+/−); wiring direction cannot be reversed
IndicatorRed / green status indication window
Isolation FunctionSome models can be used as an isolation switch

Certifications & Standards

Verified to international standards for global tenders

CE MarkingEU low voltage & EMC directives
RoHS CompliantRestricted hazardous substances
IEC Standards60898 / 60947 / 61643 / 62052
ISO 9001Quality management system
TÜV TestedIndependent lab verification
CB SchemeGlobally recognized test report

OEM / ODM Available

Private label this MCB for your brand

Logo, color housing, packaging and certificate documentation tailored to distributor and brand-owner programs.

  • Custom logo printing on housing and packaging
  • Color housing variants for product line differentiation
  • Private-label catalogs and datasheet customization
  • Project-spec drawings, single-line diagrams and labels
  • Container-load supply with export documentation
  • Sample preparation within 5–10 working days

Frequently Asked Questions

What is the difference between AC MCB and DC MCB?

AC MCBs are designed for alternating current circuits — the AC zero-crossing helps extinguish arcs naturally. DC MCBs handle direct current with no zero-crossing, requiring specialized arc-quenching contact structures and magnets. Solar PV strings, batteries and DC bus systems must use DC MCBs rated for the system Uoc.

What system voltages do your DC MCBs cover?

Standard DC MCBs cover up to 1000V DC; for utility-scale PV we offer up to 1500V DC versions using 3P / 4P series configuration.

Which curve should I choose — B, C or D?

B curve (3–5 In) for resistive loads, C curve (5–10 In) for general-purpose distribution and mixed loads, D curve (10–20 In) for inductive loads with high inrush currents like motors and transformers.

Do you support OEM branding for MCBs?

Yes — logo printing, custom housing color, dedicated packaging and private-label catalogs are supported for distributor and brand-owner programs.

Do your MCBs carry CE certification?

Yes, TPKELE MCBs are CE & RoHS compliant. AC models are tested per IEC 60898-1; DC models per IEC 60947-2. Test reports are available for project tenders and customs documentation.

How do I coordinate MCB with SPD and voltage protector in a distribution board?

Standard protection layout from upstream to downstream: (1) Main incomer AC MCB (80A–125A), (2) AC SPD Type 2 at incoming supply for surge protection, (3) Branch AC MCBs (6A–63A) for each circuit, (4) Voltage protectors on sensitive circuits downstream of branch MCBs. This sequence provides short-circuit protection (MCB), transient surge protection (SPD) and sustained voltage quality protection (voltage protector). For circuit-level earth leakage protection, use RCBOs instead of MCBs. View our AC SPD and voltage protector series.

What is the difference between AC MCB breaking capacity 6kA and 10kA?

Breaking capacity (Icn or Icu) is the maximum short-circuit current the MCB can safely interrupt. 6kA breaking capacity is standard for residential and light commercial distribution where fault current is limited by upstream impedance. 10kA is specified for commercial, industrial and high-rise buildings where higher fault currents are possible. Check the prospective short-circuit current (Isc) at the point of installation — the MCB breaking capacity must exceed Isc. When in doubt, 10kA models provide greater safety margin with minimal cost difference.

Can I use AC MCB for DC circuits or DC MCB for AC circuits?

No — AC and DC circuit breakers are not interchangeable. AC MCBs rely on the AC current zero-crossing to extinguish arcs; DC has no zero-crossing and requires specialized arc-quenching chambers and magnetic blowout. Using an AC MCB on a DC circuit (such as solar PV or battery) can result in failure to interrupt fault current, arc flash and fire hazard. Always use DC-rated MCBs for DC applications. AC MCBs are suitable only for AC distribution. View our DC MCB series for solar and battery applications.