
ATS
ATS-ST-2P Dual Power Automatic Transfer Switch
The TPKELE ATS-ST-2P is a PC-class (load-level) single-phase dual-power automatic transfer switch. It moves a 2P (live + neutral) load between two sources within ~50ms, with built-in over-voltage and under-voltage protection and auto/manual operation. Rated 63A at 110V / 220V AC in a flame-retardant PA6 housing — built for home emergency backup and RV power where fast, protected changeover matters.
Key Features
- PC class (load level) — fast changeover ≤0.05s (50ms)
- 2P (live + neutral), single phase
- 63A rated current, operating range 6A–63A
- Built-in over-voltage & under-voltage protection
- 110V / 220V AC, 50/60Hz, Auto & Manual
Need full datasheet, drawing or certificates for tender?
Typical Applications
Technical Specifications
| Product Model | ATS-ST-2P |
|---|---|
| Product Type | Dual Power Automatic Transfer Switch |
| Utilization Class | PC Class (Load Level) |
| Poles | 2P (Live + Neutral) |
| Rated Current | 63A (Operating Range: 6A – 63A) |
| Rated Voltage | 110V / 220V AC |
| Frequency | 50 / 60 Hz |
| Phase | Single Phase |
| I/O Configuration | 2 Inputs / 1 Output |
| Priority Source | Source I (Mains) |
| Compatible Sources | Mains, Inverter, Generator |
| Switching Mode | Auto & Manual |
| Transfer Time | ≤ 0.05s (50ms) |
| Over-Voltage Protection | 145V (110V mode) / 260V (220V mode) |
| Under-Voltage Protection | 85V (110V mode) / 175V (220V mode) |
| Housing Material | PA6 Flame-Retardant |
| Installation | 35mm DIN Rail |
| Conformity | CE marking, RoHS compliant |
Certifications & Standards
Verified to international standards for global tenders
OEM / ODM Available
Private label this ATS for your brand
Logo, color housing, packaging and certificate documentation tailored to distributor and brand-owner programs.
- Custom logo printing on housing and packaging
- Color housing variants for product line differentiation
- Private-label catalogs and datasheet customization
- Project-spec drawings, single-line diagrams and labels
- Container-load supply with export documentation
- Sample preparation within 5–10 working days
Frequently Asked Questions
What is the difference between the PC-class and CB-class series?
ATS-ST and ATS-W2R are PC-class (load-level) switches with very fast ~50ms changeover, ideal where short transfer time matters. STQ1 and STQ2 are CB-class motorized switches with mechanical interlock and a robust ~2s transfer, preferred for fire protection, elevators and heavy industrial backup.
What current ratings and poles are available?
All four series are rated 63A (operating range 6A–63A) and offered in 2P, 3P and 4P (ATS-ST is 2P / 4P). Contact us with your line current and phase configuration and we will confirm the right model.
Can the ATS work with diesel generators?
Yes — all series are designed for mains plus generator, inverter or backup setups. They transfer loads automatically when the primary source fails and return when mains is restored.
Do you support OEM branding for ATS?
Yes — logo, label and packaging customization are available for distributor and brand-owner programs.
What is an automatic transfer switch (ATS) and how does it work?
An automatic transfer switch (ATS) monitors the primary power source (typically mains) and automatically transfers critical loads to a secondary source (generator, inverter or backup mains) when the primary fails. When primary power is restored and stable, the ATS transfers the load back. TPKELE offers PC-class ATS (fast ~50ms transfer, solid-state or contactor) and CB-class ATS (motorized ~2s transfer with mechanical interlock). All models include auto and manual operation modes.
PC-class vs CB-class ATS — which should I choose?
PC-class ATS (load-make-before-break, ATS-ST and ATS-W2R series) offers very fast transfer time (~50ms), ideal for IT equipment, medical devices and loads sensitive to interruption. CB-class ATS (circuit-breaker + mechanical interlock, STQ1 and STQ2 series) uses motorized switching with robust mechanical interlock (~2s transfer), preferred for fire protection systems, elevators, pumps and heavy industrial loads where a short interruption is acceptable. Both classes provide reliable source transfer; select based on load sensitivity and code requirements.
Can an ATS work with solar inverters and battery backup?
Yes — TPKELE ATS models support dual-source configurations including mains + solar inverter, mains + battery inverter, or mains + diesel generator. The ATS treats any stable AC source as valid input. For solar + battery hybrid systems, the inverter output becomes the backup source, and the ATS transfers loads when the grid fails. Combine with voltage protectors downstream to protect loads from voltage transients during transfer.
What size ATS do I need for my application?
TPKELE ATS models are rated 63A working current (operating range 6A–63A). Calculate the total load current of circuits you want to transfer: sum the MCB ratings or measure actual load current. For three-phase loads, account for all three phases. Select 2P ATS for single-phase loads (1 live + neutral), 3P for three-phase delta loads (3 lines, no neutral), or 4P for three-phase wye loads (3 lines + neutral). For loads above 63A, parallel multiple ATS units or consider a contactor-based transfer panel — contact us for project-specific recommendations.
Applications







