ATS
ATS Manufacturer — Dual Power Automatic Transfer Switches
TPKELE automatic transfer switches (ATS) move critical loads between the mains and a generator, inverter or backup source automatically. Four series cover every backup-power need: ATS-ST and ATS-W2R are PC-class (load-level) switches with fast ~50ms changeover, while STQ1 and STQ2 are CB-class motorized switches with mechanical interlock and ~2s transfer. All are rated 63A at 110V / 220V AC in 2P / 3P / 4P configurations, with auto/manual operation and flame-retardant housings — built for installers, panel builders and project distributors.
- Four series — ATS-ST, ATS-W2R (PC class) and STQ1, STQ2 (CB class)
- Fast PC-class changeover ≤0.05s (50ms) on ATS-ST / ATS-W2R
- CB-class motorized transfer with mechanical interlock on STQ1 / STQ2

Frequently Asked Questions
What is the difference between the PC-class and CB-class series?
ATS-ST and ATS-W2R are PC-class (load-level) switches with very fast ~50ms changeover, ideal where short transfer time matters. STQ1 and STQ2 are CB-class motorized switches with mechanical interlock and a robust ~2s transfer, preferred for fire protection, elevators and heavy industrial backup.
What current ratings and poles are available?
All four series are rated 63A (operating range 6A–63A) and offered in 2P, 3P and 4P (ATS-ST is 2P / 4P). Contact us with your line current and phase configuration and we will confirm the right model.
Can the ATS work with diesel generators?
Yes — all series are designed for mains plus generator, inverter or backup setups. They transfer loads automatically when the primary source fails and return when mains is restored.
Do you support OEM branding for ATS?
Yes — logo, label and packaging customization are available for distributor and brand-owner programs.
What is an automatic transfer switch (ATS) and how does it work?
An automatic transfer switch (ATS) monitors the primary power source (typically mains) and automatically transfers critical loads to a secondary source (generator, inverter or backup mains) when the primary fails. When primary power is restored and stable, the ATS transfers the load back. TPKELE offers PC-class ATS (fast ~50ms transfer, solid-state or contactor) and CB-class ATS (motorized ~2s transfer with mechanical interlock). All models include auto and manual operation modes.
PC-class vs CB-class ATS — which should I choose?
PC-class ATS (load-make-before-break, ATS-ST and ATS-W2R series) offers very fast transfer time (~50ms), ideal for IT equipment, medical devices and loads sensitive to interruption. CB-class ATS (circuit-breaker + mechanical interlock, STQ1 and STQ2 series) uses motorized switching with robust mechanical interlock (~2s transfer), preferred for fire protection systems, elevators, pumps and heavy industrial loads where a short interruption is acceptable. Both classes provide reliable source transfer; select based on load sensitivity and code requirements.
Can an ATS work with solar inverters and battery backup?
Yes — TPKELE ATS models support dual-source configurations including mains + solar inverter, mains + battery inverter, or mains + diesel generator. The ATS treats any stable AC source as valid input. For solar + battery hybrid systems, the inverter output becomes the backup source, and the ATS transfers loads when the grid fails. Combine with voltage protectors downstream to protect loads from voltage transients during transfer.
What size ATS do I need for my application?
TPKELE ATS models are rated 63A working current (operating range 6A–63A). Calculate the total load current of circuits you want to transfer: sum the MCB ratings or measure actual load current. For three-phase loads, account for all three phases. Select 2P ATS for single-phase loads (1 live + neutral), 3P for three-phase delta loads (3 lines, no neutral), or 4P for three-phase wye loads (3 lines + neutral). For loads above 63A, parallel multiple ATS units or consider a contactor-based transfer panel — contact us for project-specific recommendations.